Blowing machine maintenance and maintenance precautions

Please check your exhaust time setting. If the exhaust setting is normal and it will fail if you blow it at a time, then you can judge the problem of the exhaust valve. Please open the exhaust valve to check the spring and seal.

First, the mold should be opened, and the mold should be opened and closed manually. If it is normal, run it in the empty running state, if it is normal.
Please check your exhaust time setting. If the exhaust setting is normal and it will fail every time you blow a bottle, you can judge the problem of the exhaust valve. Please open the exhaust valve to check the spring and seal. There is also a phenomenon in which the exhaust sound is relatively loud or has a bad sound.
If you are experiencing a lot of mold production and occasionally come over this kind of mold can not open the mold, please check whether the lock pin has a segment of the screw inside, in addition, please check whether the clamping force is too large, if it is too large, you should follow Standard re-adjustment.


Read more about Five Gallon Blow Molding Machine Fully Automatic Four-Mode Carousel Machine Semi-Automatic Blow Molding Machine and other related content
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn